Connection

Dariusz Dudek to Prosthesis Design

This is a "connection" page, showing publications Dariusz Dudek has written about Prosthesis Design.
Connection Strength

0.407
  1. An optical coherence tomography study of neointimal morphology and strut coverage at different time intervals from implantation of biodegradable polymer-coated sirolimus-eluting stents. Catheter Cardiovasc Interv. 2018 08 01; 92(2):302-309.
    View in: PubMed
    Score: 0.140
  2. Long-term clinical outcomes of direct absorb bioresorbable vascular scaffold implantation in acute coronary syndrome. Minerva Cardioangiol. 2019 Oct; 67(5):374-379.
    View in: PubMed
    Score: 0.040
  3. Absorb Bioresorbable Scaffold Versus Xience Metallic Stent for Prevention of Restenosis Following Percutaneous Coronary Intervention in Patients at High Risk of Restenosis: Rationale and Design of the COMPARE ABSORB Trial. Cardiovasc Revasc Med. 2019 Jul; 20(7):577-582.
    View in: PubMed
    Score: 0.039
  4. Four-year follow-up of the randomised comparison between an everolimus-eluting bioresorbable scaffold and an everolimus-eluting metallic stent for the treatment of coronary artery stenosis (ABSORB II Trial). EuroIntervention. 2018 01 20; 13(13):1561-1564.
    View in: PubMed
    Score: 0.036
  5. Comparative assessment of three drug eluting stents with different platforms but with the same biodegradable polymer and the drug based on quantitative coronary angiography and optical coherence tomography at 12-month follow-up. Int J Cardiovasc Imaging. 2018 Mar; 34(3):353-365.
    View in: PubMed
    Score: 0.035
  6. Diagnostic Accuracy of Coronary CT Angiography for the Evaluation of Bioresorbable Vascular Scaffolds. JACC Cardiovasc Imaging. 2018 05; 11(5):722-732.
    View in: PubMed
    Score: 0.034
  7. [Bioresorbable scaffolds in the treatment of coronary artery disease. Expert consensus statement of the Association of Cardiovascular Interventions of the Polish Cardiac Society (ACVI PCS)]. Kardiol Pol. 2017; 75(8):817-835.
    View in: PubMed
    Score: 0.033
  8. Scaffold and edge vascular response following implantation of everolimus-eluting bioresorbable vascular scaffold: a 3-year serial optical coherence tomography study. JACC Cardiovasc Interv. 2014 Dec; 7(12):1361-9.
    View in: PubMed
    Score: 0.029
  9. Comparison between the first and second generation bioresorbable vascular scaffolds: a six month virtual histology study. EuroIntervention. 2011 Apr; 6(9):1110-6.
    View in: PubMed
    Score: 0.022
Connection Strength

The connection strength for concepts is the sum of the scores for each matching publication.

Publication scores are based on many factors, including how long ago they were written and whether the person is a first or senior author.